Network LAN Cable Tester RJ45 RJ11 - LED Indicator
Check delivery date
Key Features
- Cable Tester for RJ12, RJ11, RJ45, Cat 5e, Cat 5, Cat 6, 10/100 Base-T, AT&T 258 A, TIA-568A/568B etc.
- Test correspondingly double-twisted cables 1, 2, 3, 4, 5, 6, 7, 8 and Ground.
- 9 LED lights to indicated wiring connection on both remote and master unit Grounding Test.
- Easy read LED display which indicates problems. Power: 9V battery (Battery not Included)
- Keep your network running smoothly by testing wrong connection, short circuit and open circuit
Specifications
- SKU
- 4321734981769
- EAN
- 4321734981769
- Product Type
- Electronic Cable
- Part Number
- LAN Cable Tester RJ11
- HSN Code
- 8423
- Connector Type
- USB Type A
- Included Components
- LAN Cable Tester RJ11
- Number of Items
- 1
- Country of Origin
- India
Product Description
WiredCom Mini Pro Network Lan Cable Tester RJ11, RJ45, RJ12, Cat 5e, Cat 5, Cat 6, 10/100 Base-T, AT&T 258 A, TIA-568A/568B Ethernet Detector Telephone cable tester (battery not included)
Functions:-
Can test correspondingly double-twisted cables 1, 2, 3, 4, 5, 6, 7, 8 and G, meanwhile, can judge wrong connection, short circuit and open circuit. 2. NS-468 tests RJ 11and RJ45
Test of double-twisted cables :-
Switch on the power. Put cables into both main tester and remote tester. The lights of the main tester will turn on sequently from 1 to G. Main tester: 1-2-3-4-5-6-7-8-G Remote tester: 1-4-3-2-5-6-7-8-G Following are abnormal..
connections :-
If one cable, for example cable NO. 3Is open circuited, the two NO. 3 Lights of The main tester and remote tester will not turn on.
If several cables are not connected, several lights will not turn on respectively. If less than two cables are connected, none of the lights is on.
If two ends of a cable is disordered, for example NO. 2 And NO. 4, Then displays on: Main tester: 1-2-3-4-5-6-7-8-G in tester: 1-2-3-4-5-6-7-8-G Remote tester: 1-4-3-2-5-6-7-8-G 4. If two cables are short circuited, neither of the corresponding lights is on of the remote tester while main tester remains unchanged. If three cables, including three, are short circuited, none of the corresponding lights is on
If test patch panels or wall plate outlels, two cables which can match each other(eg110 P4 and RJ45)will be connected to the tester.
Main tester :-
Size: 106*68*27mm
Weight: 68g